The welcome visits Shandong Hairui Zhonglian Pump Industry Co. , ltd. Website, the conduit pump that my company is a major produces manufacturer. When you need conduit pump type selecting, we will provide the before-sales service such as price of pump of conduit pump model, conduit, in order to offer your referenced alternative. This product information is about chemical conduit pump shaft coupling searchs knowledge:
The connective of shaft coupling place of chemical conduit pump and electric machinery the whirl of two axes center should strict homocentric, shaft coupling must search accurately when installation, in be opposite, will cause very great stress on shaft coupling otherwise, will affect the regular job of other part on bearing and axis, axis severely, the vibration that causes whole platform machine and foundation even or attaint. Accordingly, of pump and electric machinery shaft coupling searching is one of very important work segment in installation and overhaul process.
Shaft coupling looks for the analysis that is deflection circumstance:
Installing newConduit pumpWhen, to shaft coupling end panel and axes the verticality between need not make an inspection, but when installing old pump, must check carefully, should adjust when discovery is not perpendicular perpendicular hind reentry searchs all right. Usually, encounter possibly have the following 4 kinds of case.
1) S1=S2, a1=a2 two half back of a chair annulus end panel is to be in already parallel homocentric proper place, at this moment two axes must be located in to go up point-blank.